HT9022
EN - 41
5.7. POSITION ”: RESISTANCE AND CONTINUITY MEASUREMENT
WARNING
Before attempting any resistance measurement, remove power from the
circuit under test and discharge all capacitors, if present.
By positioning the selector switch to “ ”, the screen to the side
will appear.
Mod OK Fnz
> 60.0 k
19/01-17:00:00
Fig. 13: resistance measurement
Insert the red cable into the input lead V and the black cable into the input lead COM,
and connect the instrument as described in Fig. 13.
Press key F1 (Mod) to open the drop-down menu shown on the
screen to the side. At each subsequent pressure of key F1, the
cursor will scroll through the available items, as follows:
Resistance: resistance measurement;
Continuity: continuity measurement;
Help: it displays the connection between instrument and
system;
Esc: it closes the drop-down menu.
Mod OK Fnz
> 60.0 k
19/01-17:00:00
Select the desired mode and press key F3 (OK) to confirm.
Resistance
Continuity
Help
Esc