Ht-instruments PVCHECK Manual de usuario Pagina 37

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 36
PVCHECK
EN - 35
Fig. 8: Connection for IVCK test with direct irradiance measurement
CAPTION:
E: Green cable
C: Blue cable
P: Red cable
N: Black cable
1. PV module/string
2. Main system earthing
3. Earthed metal structure in the
system
4. Reference cell for irradiance
measurement
5. Temperature sensor (if
required)
6. Unità remota SOLAR-
02Remote unit SOLAR-02
Fig. 9: Connection for IVCK test with irradiance measurement through SOLAR-02
14. In the initial screen of IVCK mode, the following values
are displayed in real time:
Module type of module being tested
Vdc value of output voltage from module/string
Irr irradiance (from a direct measurement or
SOLAR-02 connected via RF)
Tc modulo temperature (in MAN or AUX mode) and
the relevant measuring mode, or “- - -” in AUTO mode
In case, the symbol “ ” of RF connection with
SOLAR-02
15/05/12 15:34:26
Module : SUNPWR318
Vdc : 548.0 V
Irr : 856 W/m2
Tc : Auto °C
Voc,Isc:
Ri(1000V) - - -
M
Rpe (Cal) - - -
Selezione
IVCK
CAUTION
Upon pressing the GO/STOP key, different error messages can be displayed
by the instrument (see § 6.6) and, therefore, the test cannot be started. Check
and eliminate, if possible, the problem causing the error message before going
on with the test.
15. Press GO/STOP to start the test. In case no erro
r
conditions occur, the instrument displays the message
Measuring…” and the measure of open-circuit voltage
between the terminals P and N and of short-circuit current
(for Isc values 10A).
15/05/12 15:34:26
Module : SUNPWR318
Vdc : 548.0 V
Irr : 856 W/m2
Tc : Auto °C
Voc,Isc:
Ri(1000V) - - -
M
Rpe (Cal) - - -
Measuring…
Selection
IVCK
Vista de pagina 36