PVCHECK
EN - 60
10.2. TECHNICAL SPECIFICATIONS OF THE IVCK FUNCTION
DC Voltage @ OPC
Range [V] Resolution [V] Accuracy
5.0 199.9
0.1
(1.0rdg + 2dgt)
200 999
0.5
Minimum VPN voltage to start the test: 15V
DC Current @ OPC
Range [A] Resolution [A] Accuracy
0.10 10.00
0.01
(1.0rdg + 2dgt)
DC Voltage @ STC
Range [V] Resolution [V] Accuracy
5.0 199.9
0.1
(4.0rdg + 2dgt)
200 999
1
DC Current @ STC
Range [A] Resolution [A] Accuracy
0.10 10.00
0.01
(4.0rdg + 2dgt)
Irradiance (with HT304N reference cell)
Range [mV] Resolution [mV] Accuracy
1 40.0
0.02
(1.0rdg + 0.1mV)
Temperature (with probe type PT300N)
Range [°C] Resolution [°C] Accuracy
-20.0 100.0
0.1
(1.0rdg + 1°C)
10.3. TECHNICAL SPECIFICATIONS FOR ELECTRICAL SAFETY
Continuity of protective conductors (LOW)
Range [] Resolution []
Accuracy
0.00 1.99
0.01
(2.0rdg + 2dgt)
2.0 19.9
0.1
20 199
1
Test current >200mA DC up to 5 (cables included), resolution 1mA, accuracy (5.0%reading + 5digits)
Open-circuit voltage 4 < V
0
< 10V
Insulation resistance (M) – Mode TIMER
Test voltage [V]
Range [M] Resolution [M]
Accuracy
250, 500, 1000
0.01 1.99
0.01
(5.0rdg + 5dgt)
2.0 19.9
0.1
20 199
1
Open voltage <1.25 x nominal test voltage
Short circuit current < 15mA (peak) for each test voltage
Generated voltage resolution 1V, accuracy (5.0%reading + 5digits) @ Rmis> 0.5% FS
Rated current measured > 1mA with 1k @ Vnom
Insulation resistance (M) – Mode FIELD (*), STRING (**)
Test voltage [V]
Range [M] Resolution [M]
Accuracy (***)
250, 500, 1000
0.1 1.9
0.1
(20.0rdg + 5dgt)
2 99
1
(*) For FIELD mode if VPN >1V the minimum voltage VEP and VEN for the calculation of Ri(+) and Ri(-) is 1V
(**) For STRING mode minimum VPN voltage to start the test: 15V
Open voltage <1.25 x nominal test voltage
Short circuit current < 15mA (peak) for each test voltage
Generated voltage resolution 1V, accuracy (5.0%reading + 5digits) @ Rmis> 0.5% FS
Rated current measured > 1mA with 1k @ Vnom
(***) For FIELD mode: add 5 dgts to the accuracy if
100
,min
,max
RR
RR
Comentarios a estos manuales