6. For M test in STRING mode there are the values of the
following parameters:
Set rated test voltage
Minimum threshold set on insulation measurement
The type of mode selected
The real value of the applied test voltage
The Rp final value of the measurement obtained by
the parallel of Ri(+) e Ri(-) values which is compared
with the Ri min limit by the instrument
15/05/12 15:34:26
Ins. Test : 1000 V
Ri min : 1.0 M
Mode : String
Vtest 1020 V
Rp >200
M
Outcome: OK
Selection
M
7. For LOW test, there are the values of the following
parameters:
Limit threshold set for continuity measurement
Value of calibration resistance of test cables
The value of resistance of the object being tested
The real value of the applied test current
15/05/12 15:34:26
RPE max : 1.0
Rcal : - - -
Rpe = 0.99
Itest = 212. mA
Outcome: OK
Selection
LOW
7.3.3. Deleting data from the memory
1. Within the list of saved results, press ENTER to display
the submenus.
2. Select “Delete”, then press . The instrument allows
selecting the following items:
Delete Last deletes the last saved test
Delete All deletes the whole memory content
3. Use the arrow keys (,) to select the desired option,
then press the ENTER key to confirm selection
4. Press ESC/MENU to exit the screen and go back to the
main menu.
15/05/12 15:34:26
MEM TYPE
001 SMP 08/04/2012
002 REC 13/04/2012
Recall
Open Delete Last
Delete Delete All
Selection
MEM EFF
Vista de pagina 57